高级搜索
吴娟, 张雅琴, 吴云彬, 陈敏, 于洲, 曹颖平. S-poly(T)plus荧光定量PCR技术在检测肝癌相关miR-199中的临床应用价值[J]. 肿瘤防治研究, 2020, 47(10): 761-765. DOI: 10.3971/j.issn.1000-8578.2020.19.1618
引用本文: 吴娟, 张雅琴, 吴云彬, 陈敏, 于洲, 曹颖平. S-poly(T)plus荧光定量PCR技术在检测肝癌相关miR-199中的临床应用价值[J]. 肿瘤防治研究, 2020, 47(10): 761-765. DOI: 10.3971/j.issn.1000-8578.2020.19.1618
WU Juan, ZHANG Yaqin, WU Yunbin, CHEN Min, YU Zhou, CAO Yingping. Clinical Value of S-poly (T) plus Real-time PCR in Detection of Liver Cancer-related miR-199[J]. Cancer Research on Prevention and Treatment, 2020, 47(10): 761-765. DOI: 10.3971/j.issn.1000-8578.2020.19.1618
Citation: WU Juan, ZHANG Yaqin, WU Yunbin, CHEN Min, YU Zhou, CAO Yingping. Clinical Value of S-poly (T) plus Real-time PCR in Detection of Liver Cancer-related miR-199[J]. Cancer Research on Prevention and Treatment, 2020, 47(10): 761-765. DOI: 10.3971/j.issn.1000-8578.2020.19.1618

S-poly(T)plus荧光定量PCR技术在检测肝癌相关miR-199中的临床应用价值

Clinical Value of S-poly (T) plus Real-time PCR in Detection of Liver Cancer-related miR-199

  • 摘要:
    目的 探讨S-poly(T) plus荧光定量PCR法与普通Poly(A)加尾法检测外周血血清miR-199敏感度的优劣性。
    方法 采用荧光定量PCR S-poly(T) plus法和Poly(A)加尾法检测肝癌患者和健康人血清miR-199,分别从敏感度、线性关系和重复性三方面进行评估其潜在临床应用价值。
    结果 S-poly (T) plus法检测健康人miR-199的Ct值显著低于Poly(A)加尾法(30.32±0.72 vs. 35.42±0.67, P < 0.0001);而且S-poly(T) plus法具有更好的线性关系(R2=0.9843±0.0047 vs. R2=0.9573±0.0045, P=0.0027)和更好的的重复性(CV=2.59% vs. CV=3.52%, P=0.010)。S-poly (T) plus法在检测肝癌患者外周血miR-199时具有更好的敏感度。
    结论 S-poly (T) plus荧光定量PCR检测肝癌血清miR-199比Poly(A)加尾法敏感度更高、重复性及稳定性更优。

     

    Abstract:
    Objective To explore the advantages and disadvantages of S-poly(T) plus qRT-PCR and Poly (A) qRT-PCR methods in detecting peripheral blood serum miR-199.
    Methods S-poly(T) plus RT-PCR and Poly(A) qRT-PCR methods were used to detect the serum miR-199 in patients with liver cancer and healthy controls in three aspects of sensitivity, linearity and repeatability to evaluate their potential clinical value.
    Results The Ct values of S-poly(T) plus qRT-PCR method for miR-199 in healthy controls was significantly lower than that of Poly(A) qRT-PCR method (P < 0.0001); and the S-poly(T) plus qRT-PCR method had better linear correlation (P=0.0027) and repeatability (P=0.010). S-poly(T) plus qRT-PCR method had better sensitivity in detecting serum miR-199 in liver cancer patients comparing with Poly (A) qRT-PCR method.
    Conclusion In the detection of liver cancer serum miR-199, S-poly(T) plus qRT-PCR method is more sensitive, repeatable and stable than Poly(A) qRT-PCR.

     

/

返回文章
返回